Model: FRONT/L
Fault Code | Fault |
8 |
MOTOR NOT TURNING DURING WASH CYCLE
|
10 |
MOTOR SENSED NOT TURNING DURING SPIN CYCLE
|
17 |
DOOR WAS NOT LOCKED AT THE END OF THE FINAL SPIN
|
19 |
WATER LEVEL REACHED BUT NOT MAINTAINED DURING CYCLE
|
30 |
SHUT DOWN DUE TO MOTOR SPEED ERROR DURING WASH
|
31 |
SPIN CYCLE WAS DELAYED AS WATER STILL IN DRUM
|
32 |
UNBALANCE BELOW 500RPM
|
33 |
SUDS DETECTED DURING WASH CYCLE
|
34 |
SPINNING BELOW 85RPM TOO LONG DURING SPIN CYCLE
|
35 |
TUMBLING ABOVE 50RPM TOO LONG DURING WASH CYCLE
|
36 |
MOTOR NOT SLOWING DOWN AFTER 120SEC'S OF COASTING AFTER REACHING 300RPM
|
37 |
SPEED ERROR, MOTOR RUNNING TOO FAST,COULD BE OPTIC SENSOR AT FAULT
|
39 |
MOTOR STILL RUNNING AFTER 120SEC'S OF COASTING AFTER UNBALANCE
|
40 |
MOTOR RUNNING FASTER THAN 85RPM AND DOOR NOT LOCKED
|
71 |
DEBIT CARD READER MESSAGING PROBLEM
|
74 |
DEBIT CARD READER MESSAGING PROBLEM
|
75 |
DEBIT CARD READER MESSAGING PROBLEM
|
1b |
SLOW FILL LEVEL NEVER REACHED
|
1d |
UNBALANCE WITHIN SPIN GREATER THAN 500RPM AND LESS THAN 675RPM
|
2A |
MOTOR ON A FULL POWER FOR 15SEC'S DURING FINAL SPIN
|
2F |
SHUT DOWN DUE TO MOTOR SPEED ERROR DURING SPIN
|
d10 |
DOOR LOCK SENSE ERROR,SPINS INHIBITED
|
d11 |
SPEED ERROR,COULD BE OPTIC SENSOR AT FAULT
|
Model: L/C
Fault Code | Fault |
d1 |
DRIER DOOR SENSE ERROR
|
d2 |
WASHER DOOR SENSE ERROR
|
d4 |
DRIER MOTOR CONTROL CIRCUIT ERROR
|
Model: TOP/L
Fault Code | Fault |
d1 |
WATER LEVEL DETECTION ERROR ON CONTROL BOARD
|
d12 |
MOTOR SENSE ERROR DETECTED ON CONTROL BOARD
|
Model: STACK D
Fault Code | Fault |
d12 |
LOWER MOTOR SENSOR CIRCUIT FAILURE
|
d14 |
UPPER MOTOR SENSOR CIRCUIT FAILURE
|
d18 |
UPPER THERMISTOR CIRCUIT FAILURE
|
d19 |
UPPER DRIER TEMP TOO HIGH
|
d2 |
LOWER THERMISTOR CIRCUIT FAILURE
|
d20 |
UPPER DRIER MOTOR CONTROL CIRCUIT FAILURE
|
d21 |
LOWER MOTOR SENSED RUNNING WHEN IT SHOULD BE OFF
|
d22 |
UPPER MOTOR SENSED RUNNING WHEN IT SHOULD BE OFF
|
d23 |
CONTROL BOARD IS NOT CALIBRATED FOR THERMISTORS
|
d3 |
LOWER DRIER TEMP TOO HIGH
|
d4 |
LOWER DRIER MOTOR CONTROL CIRCUIT FAILURE
|
Model: ALL
Fault Code | Fault |
d13 |
BLOCKED COIN 2
|
d16 |
CONTROL NOT RECEIVING COMMUNICATIONS FRON DEBIT CARD READER
|
d4 |
WASHER LID SENCE ERROR ON CONTROL BOARD
|
d5 |
BLOCKED COIN 1
|
d7 |
LAST FILL WAS SLOW
|
d8 |
LAST DRAIN DURING FINAL SPIN WAS SLOW
|
d9 |
VOLTAGE BELOW 90Vac FOR 8 SECONDS
|
Model: HELP MODE SYMBOLS MAYTAG WASHER FRONT LOADER MAH14 MODELS
Fault Code | Fault |
DISPLAY=WASH |
WATER SENSED AT WATER LEVEL
|
DISPLAY=* |
LOW VOLTAGE PRESENT(BELOW ABOUT 90 VAC)
|
DISPLAY= RE |
REDISTRIBUTING OUT OF BALANCE LOAD(CHECK OUT OF BALANCE SWITCH WIRING) IF NO MOTOR ACTION BUT OUT OF BALANCE SYSTEM CHECKED CHECK MOTOR/CONTROL
RECIRCULATION PUMP RELAY ON
|
DISPLAY=CIRCLE ABOVE DIGIT |
DOOR CLOSED
|
DISPLAY=DOOR LOCKED |
DOOR SENSED LOCKED
|
DISPLAY=COLD |
COLD WATER RELAY ON
|
DISPLAY=HOT |
HOT WATER RELAY ON
|
DISPLAY=SOFTENER |
DOOR LOCK RELAY ON
SOFTENER DISPENSE RELAY ON
|
DISPLAY=BLEACH |
DRAIN RELAY ON
BLEACH RELAY ON
|
DISPLAY= UNBALANCE |
REDISTRIBUTING OUT OF BALACE LOAD(CHECK OUT OF BALANCE SW WIRING)
|
DISPLAY= OR |
DOOR LOCK RELAY ON
|
DISPLAY=AVAILABLE |
DRAIN RELAY ON
|
Model: MAYTAG FRONT LOADER
Fault Code | Fault |
8 |
MOTOR SENSED NOT TURNING DURING WASH
|
F |
SUDS LOCK POSSIBLE MCH OVERLOAD WHEN SPINING LESS THAN 500 RPM
|
10 |
MOTOR SENSED NOT TURNING DURING SPIN CYCLE
|
17 |
DOOR NOT LOCKEDAT THE END OF FINAL SPIN CHECK MICRO SWITCH AND WIRING
|
19 |
WATER LEVEL WAS REACHED DURING THE WASH CYCLE BUT THE WATER LEVEL WAS NOT MAINTAINED SLOW FILL OR WATER DRAINING OUT OF THE TUB
|
1b |
SLOW FILL WATER WAS NEVER REACHED LOW WATER PRESSURE FAULTY WATER VALVE TURN ON EX FILL FOR A LONGER FILL TIME IF WATER PRESSURE IS LOW
|
1d |
UNBALANCE WITHIN A SPIN AT GREATER THAN 500RPM AND LESS THAN 675RPM DURING THE FINAL SPIN CYCLE CHECK OUT OF BALANCE SWITCHES AND WIRING OR OUT OF BALANCE LOAD MOTOR ON FULL POWER FOR 15 SECONDS DURING THE FINAL SPIN AT 500RPM AND LESS THAN
|
2A |
675RPM POSSIBLE OVERLOADED MCH POSSIBLE LOSS OF A PHASE ON THE MOTOR
|
2F |
SHUT DOWN DUE TO MOTOR SPEED ERROR DURING SPIN FAULT WITHIN MOTOR ?
|
30 |
SHUT DOWN DUE TO MOTOR SPEED ERROR DURING WASH CYCLE FAULT WITHIN MOTOR ?
|
31 |
SPIN CYCLE DELAYED WASH LEVEL SENSED FOR MORE THAN 60 SEC,S DRAIN PUMPFAULT ?
|
32 |
UNBALANCE AT LESS THAN 500RPM DURING THE FINAL SPIN, SPIN CYCLE STOPPED CHECK OUT OF BALANCE SWITCHES WIRING OUT OF BALANCE LOAD
|
33 |
SUDS DETECTED DURING WASH CYCLE
|
34 |
SPINNING BELOW 85RPM TOO LONG DURING THE SPIN CYCLE MOTOR FAULT?
|
Need assistance with your Maytag machine? Call us now on [ld_default] to book an engineer. We’re always here to help