Girbau Error Codes
Seeing an error code on your Girbau machine but don’t know what it means? Have a look at our code guide below.
Model: HS-5008
Fault Code | Fault |
ALM/A-* |
FAULTY WATER INLET / SLOW FILL
|
ALM/E |
MACHINES WITH PUMP DRAIN BLOCKED DRAIN/PUMP
|
ALM/L |
LEAKAGE IN THE ELECTROVALVE(failed level sensor)
|
ALM/SL |
BATH LEVEL EXCEEDED
|
ALM/C |
DEFECT IN TEMP PROBE/DEFECT IN HEATING CIRCUIT
|
ALM/Prob |
DEFECT IN TEMP PROBE
|
ALM/BAL |
DEFECT IN THE UNBLANCE CONTROL SWITCH (OPEN CIRCUIT)
|
ALM/VAR* |
INVERTER ALARMS.SEE INVERTER FAULT CODES
|
VARO |
COMMUNICATION ALARM BETWEEN INVERTER AND MICROPROCESSOR
FAULTY INVERTER SUPPLY, FAULTY WIRING BETWEEN MICROPROCESSOR
|
VAR1 |
DISCONNECTION OF INVERTER BY SELF-PROTECTION,IF THE ALARM IS PERMANENT INDICATES INVERTER BREAKDOWN
|
VAR2 |
FAILURE ON THE COMMUNICTION SYSTEM DETECTED BY THE INVERTER
INVERTER BREAK DOWN, MICROPROCESSOR BREAK DOWN
|
VAR3 |
OVER CURRENT IN INVERTER
MECHANICAL OBSTRUCTION OF THE TRANSMISSION SYSTEM
FAULTY INVERTER SUPPLY
FAULTY WIRING OR CONN TO MOTOR
FAULTY MOTOR
FAULTY INVERTER
|
VAR4 |
DISCONNECTION OF MOTOR KLIXON
MOTOR KILXON OPEN
FAULTY INVERTER
|
VAR5 |
OVER VOLTAGE IN INVERTER DC LINT CIRCUIT
FAULTY INVERTER SUPPLY
INVERTER BREAK DOWN
|
VAR6 |
OVERHEATING IN INVERTER
INVERTER FAN BREAKDOWN/INVERTER
|
VAR7 |
FAILURE IN INVERTER
FAULTY INVERTER
|
VAR8 |
INVERTER BREAKDOWN
|
Need assistance with your Girbau machine? Call us now on [ld_default] to book an engineer. We’re always here to help